Skip to main content

Cabinet laser profile

OMTech Maker AF2028-60

A record based on manufacturer sources for room and delivery planning. It does not certify the room, circuit, ventilation, material, or fire-safety setup.

Direct answer: the recorded closed body is 47.2 × 34.3 × 36.6 in; the unopened package is 52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm. Operating clearance remains a separate check.

  • Published envelope recorded
  • Profile reviewed
  • No inferred package or clearance values
01 · Physical profile

The published machine envelope

Assembled size

47.2 × 34.3 × 36.6 in

Manufacturer-published assembled envelope.

Machine weight

249.1 lb / 113 kg

Verify the complete operating load and supporting surface separately.

Work area

19.7 × 27.6 in / 500 × 700 mm

Processing area is not the required room footprint.

Delivery package · published

52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm

Published shipping weight: Not published in cited sources. Confirm the exact bundle before delivery.

02 · Installation profile

Requirements to carry into the site plan

Exhaust

Route and connection

Two 150 mm × 1.5 m pipes, clamps, and a fan are supplied; keep routing sealed, short, and straight

Electrical

Nameplate input

110–120 VAC, 60 Hz; published power consumption of 700 W

Cooling

Cooling components

Plan supplied and external cooling components according to the current manual

Clearance

Access in use

No numeric clearance is published; side and rear access panels and vents require access.

03 · Resolve before ordering

Open checks remain part of the answer.

Package envelope

Confirm the exact shipped bundle.

52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm. The cited size is a useful starting point, but seller packaging and bundled accessories can change the delivery envelope.

Operating envelope

Measure access in use.

No numeric clearance is published; side and rear access panels and vents require access. Any optional room allowance is user-selected and is not a manufacturer minimum.

  • External discharge or a dedicated fume extractor must follow emissions and applicable rules.
05 · Continue the plan

Use the measurements in context.

Delivery

Delivery-path calculator

Prefill sourced package evidence and test every rectangular opening in route order.

Projects

Project-fit checker

Compare a measured flat project with documented work areas and optional 90-degree rotation.

Scale drawing

Workshop layout planner

Place the sourced closed body, support, entered operating zone, air-management equipment, and keep-clear rectangle.

Compare

Installation comparison builder

Put this evidence beside up to two other current profiles without hiding incomplete fields.

Placement

Operating-footprint planner

Add documented lid, service and material allowances to the closed footprint.

Exhaust

Vent-route planner

Prefill the machine note, then map segments, bends, transitions, endpoint, and confirmations without guessing airflow.

Utilities

Electrical pre-check

Inventory the machine and accessory nameplates for a qualified electrician.

Open data

Installation geometry row

Compare delivery, closed, exhaust, electrical, and numeric-clearance evidence in the downloadable dataset.

Change record

Specification tracker

Inspect the dated observation baseline and any later retained changes to manufacturer documentation.

Template

Workshop planning record

Lay out the support, operating zone, accessories, and electrical-load inventory together.

Publisher asset

Embed this True Footprint card

Copy an auto-updating iframe or dated HTML badge with evidence states, review date, and room-check backlink.

Complete plan

Laser-room setup checklist

Carry delivery, operating space, air path, utilities, materials, documentation, and professional confirmations into one record.

06 · Related profiles
07 · Official evidence

Manufacturer sources used for this profile

Source links are editorial evidence, not paid links. Open the current source and match it to the exact region, model, and configuration.

08 · Plain-language answers

Common room-planning questions about Maker AF2028-60

What are the published OMTech Maker AF2028-60 dimensions?

The recorded closed-body envelope is 47.2 × 34.3 × 36.6 in. It does not include lid, service, duct, accessory, or material-travel clearance.

Are OMTech Maker AF2028-60 shipping dimensions published?

The recorded package is 52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm. Confirm the exact bundle and freight instructions before delivery.

How much room does OMTech Maker AF2028-60 need?

The closed body is only the starting envelope. No numeric clearance is published; side and rear access panels and vents require access. Measure the lid, controls, access panels, exhaust, cables, accessories, material travel, egress, and service access in the actual arrangement.

What exhaust and electrical evidence is recorded for OMTech Maker AF2028-60?

Exhaust: Two 150 mm × 1.5 m pipes, clamps, and a fan are supplied; keep routing sealed, short, and straight Electrical: 110–120 VAC, 60 Hz; published power consumption of 700 W These notes organize confirmation and do not approve a ventilation or electrical design.

Use the profile to organize professional checks—not replace them.

Verify the exact machine and accessory nameplates, grounding, circuit and local requirements with a licensed electrician. Install exhaust exactly as the manufacturer directs and resolve discharge, filtration and material emissions under applicable rules. Never leave active processing unattended.

Compare OMTech Maker AF2028-60 with your delivery path and workspace.

Use the manufacturer profile as a starting point, then enter the room and route you actually measured.

Check my room for Maker AF2028-60