Cabinet laser profile
OMTech Maker AF2028-60
A record based on manufacturer sources for room and delivery planning. It does not certify the room, circuit, ventilation, material, or fire-safety setup.
Direct answer: the recorded closed body is 47.2 × 34.3 × 36.6 in; the unopened package is 52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm. Operating clearance remains a separate check.
- Published envelope recorded
- Profile reviewed
- No inferred package or clearance values
The published machine envelope
47.2 × 34.3 × 36.6 in
Manufacturer-published assembled envelope.
249.1 lb / 113 kg
Verify the complete operating load and supporting surface separately.
19.7 × 27.6 in / 500 × 700 mm
Processing area is not the required room footprint.
52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm
Published shipping weight: Not published in cited sources. Confirm the exact bundle before delivery.
Requirements to carry into the site plan
Route and connection
Two 150 mm × 1.5 m pipes, clamps, and a fan are supplied; keep routing sealed, short, and straight
Nameplate input
110–120 VAC, 60 Hz; published power consumption of 700 W
Cooling components
Plan supplied and external cooling components according to the current manual
Access in use
No numeric clearance is published; side and rear access panels and vents require access.
Open checks remain part of the answer.
Confirm the exact shipped bundle.
52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm. The cited size is a useful starting point, but seller packaging and bundled accessories can change the delivery envelope.
Measure access in use.
No numeric clearance is published; side and rear access panels and vents require access. Any optional room allowance is user-selected and is not a manufacturer minimum.
- External discharge or a dedicated fume extractor must follow emissions and applicable rules.
Use the measurements in context.
Delivery-path calculator
Prefill sourced package evidence and test every rectangular opening in route order.
ProjectsProject-fit checker
Compare a measured flat project with documented work areas and optional 90-degree rotation.
Scale drawingWorkshop layout planner
Place the sourced closed body, support, entered operating zone, air-management equipment, and keep-clear rectangle.
CompareInstallation comparison builder
Put this evidence beside up to two other current profiles without hiding incomplete fields.
PlacementOperating-footprint planner
Add documented lid, service and material allowances to the closed footprint.
ExhaustVent-route planner
Prefill the machine note, then map segments, bends, transitions, endpoint, and confirmations without guessing airflow.
UtilitiesElectrical pre-check
Inventory the machine and accessory nameplates for a qualified electrician.
Open dataInstallation geometry row
Compare delivery, closed, exhaust, electrical, and numeric-clearance evidence in the downloadable dataset.
Change recordSpecification tracker
Inspect the dated observation baseline and any later retained changes to manufacturer documentation.
TemplateWorkshop planning record
Lay out the support, operating zone, accessories, and electrical-load inventory together.
Publisher assetEmbed this True Footprint card
Copy an auto-updating iframe or dated HTML badge with evidence states, review date, and room-check backlink.
Complete planLaser-room setup checklist
Carry delivery, operating space, air path, utilities, materials, documentation, and professional confirmations into one record.
Compare another room-planning envelope.
Manufacturer sources used for this profile
Source links are editorial evidence, not paid links. Open the current source and match it to the exact region, model, and configuration.
Common room-planning questions about Maker AF2028-60
What are the published OMTech Maker AF2028-60 dimensions?
The recorded closed-body envelope is 47.2 × 34.3 × 36.6 in. It does not include lid, service, duct, accessory, or material-travel clearance.
Are OMTech Maker AF2028-60 shipping dimensions published?
The recorded package is 52.0 × 39.0 × 44.9 in / 1320 × 990 × 1140 mm. Confirm the exact bundle and freight instructions before delivery.
How much room does OMTech Maker AF2028-60 need?
The closed body is only the starting envelope. No numeric clearance is published; side and rear access panels and vents require access. Measure the lid, controls, access panels, exhaust, cables, accessories, material travel, egress, and service access in the actual arrangement.
What exhaust and electrical evidence is recorded for OMTech Maker AF2028-60?
Exhaust: Two 150 mm × 1.5 m pipes, clamps, and a fan are supplied; keep routing sealed, short, and straight Electrical: 110–120 VAC, 60 Hz; published power consumption of 700 W These notes organize confirmation and do not approve a ventilation or electrical design.
Verify the exact machine and accessory nameplates, grounding, circuit and local requirements with a licensed electrician. Install exhaust exactly as the manufacturer directs and resolve discharge, filtration and material emissions under applicable rules. Never leave active processing unattended.