Desktop laser profile
OMTech K40+ 45W
A manufacturer-source record for room and delivery planning. It does not certify the room, circuit, ventilation, material or fire-safety setup.
- Published envelope recorded
- Checked
- No inferred package or clearance values
The published machine envelope
31.9 × 19.7 × 9.8 in
Manufacturer-published assembled envelope.
83.8 lb / 38 kg
Verify the complete operating load and supporting surface separately.
8 × 12 in / 200 × 300 mm
Processing area is not the required room footprint.
Not published in cited sources
Do not substitute assembled dimensions for the unopened package.
Requirements to carry into the site plan
Route and connection
Exhaust pipe and clamp supplied; diameter and required airflow not published in cited sources
Nameplate input
AC input and total machine consumption not published in cited sources
Cooling components
Water pump supplied; plan water-cooling components per current manual
Access in use
No numeric lid or service clearance published in cited sources.
Open checks remain part of the answer.
Get the shipping dimensions.
Not published in cited sources. Ask the seller or manufacturer for the exact packaged width, depth, height and weight for the SKU being delivered.
Measure access in use.
No numeric lid or service clearance published in cited sources. Any optional room allowance is user-selected and is not a manufacturer minimum.
- OMTech says not to operate when the exhaust system is not working.
Verify the exact machine and accessory nameplates, grounding, circuit and local requirements with a licensed electrician. Install exhaust exactly as the manufacturer directs and resolve discharge, filtration and material emissions under applicable rules. Never leave active processing unattended.