Skip to main content

Desktop laser profile

xTool F2 Ultra Single 60W MOPA

A record based on manufacturer sources for room and delivery planning. It does not certify the room, circuit, ventilation, material, or fire-safety setup.

Direct answer: the recorded closed body is 11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm; the unopened package is not fully published for a general current shipment. Operating clearance remains a separate check.

  • Official sources conflict
  • Profile reviewed
  • No inferred package or clearance values
Do not issue an assembled-fit pass from this profile.

The cited official sources disagree. Confirm the exact delivered model, current manual and nameplate before entering a planning dimension or input rating.

01 · Physical profile

The published machine envelope

Assembled size

11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm

Official values conflict; numeric fit checking is disabled.

Machine weight

45 lb / 20.8 kg

Verify the complete operating load and supporting surface separately.

Work area

8.66 × 8.66 in / 220 × 220 mm; 8.66 × 19.69 in / 220 × 500 mm with Auto Streamline Conveyor

Processing area is not the required room footprint.

Delivery package · unresolved

Not published in cited sources

Published shipping weight: Not published in cited sources. Confirm the exact bundle before delivery.

Laser configuration

60 W 1064 nm MOPA infrared only

Use current manufacturer guidance for the exact material and process.

Safety classification

Class 4 (MXF-K004-002)

Match the ordered and delivered model to its current instructions and site controls.

Maximum object-height evidence

150 mm published maximum

A published maximum is not an operating clearance, material approval, focus guarantee, or proof a fixture will fit.

02 · Installation profile

Requirements to carry into the site plan

Exhaust

Route and connection

80 mm smoke-exhaust pipe in current compatibility guidance

Electrical

Nameplate input

Power-adapter input 100–240 VAC, 50/60 Hz; the family listing states 400 W maximum but does not isolate a Single-only maximum

Cooling

Cooling components

No external water-cooling requirement stated in cited sources

Clearance

Access in use

No numeric operating, service, conveyor-travel, hose-bend, cable, or accessory clearance published in cited sources.

03 · Resolve before ordering

Open checks remain part of the answer.

Package envelope

Get the shipping dimensions.

Not published in cited sources. Ask the seller or manufacturer for the exact packaged width, depth, height and weight for the SKU being delivered.

Operating envelope

Measure access in use.

No numeric operating, service, conveyor-travel, hose-bend, cable, or accessory clearance published in cited sources. Any optional room allowance is user-selected and is not a manufacturer minimum.

Official-source conflict

Resolve the published disagreement.

11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm. Do not silently choose one value.

  • This is the Single-laser configuration; it does not include the 40 W blue-light diode laser. On xTool's shared listing, select ‘Single Laser (60W MOPA Only)’. This Class 4 professional-use model does not establish permission to operate around the public or bystanders.
  • The 400 W family-page maximum is not presented here as a confirmed Single-only draw.
  • The support guide lists the height as 520 mm; the product page lists it as 521 mm. The 1 mm documentation difference is retained and is not usable clearance.
  • The standard package lists a touchscreen and smoke-exhaust pipe; an external purifier is not assumed unless the selected bundle says so. Route outdoors or confirm an exact compatible filtration arrangement.
  • As of September 14, 2026, observed seller choices included Standalone, Conveyor, and Deluxe packages; contents, prices, and availability can change.
Paid link: LaserRoomReady may earn a commission at no extra cost to you if you buy through this link.

Commissions do not change fit results or profile ordering. The seller controls availability, pricing, attribution, returns and the transaction.

Open xTool's shared F2 Ultra listing and select ‘Single Laser (60W MOPA Only)’
04 · Compatible planning profiles

Plan the accessories that change the room.

Compatibility below comes from the cited manufacturer material. Every accessory still needs its own footprint, load, delivery and operating-path check.

05 · Continue the plan

Use the measurements in context.

Room dimensions answer only part of the purchase question. Check the task and material evidence, record the software handoff, then review the exact quote.

Configuration

F2 Ultra Single vs Dual

Compare laser systems, published machine weight, shared closed dimensions, and order-specific evidence gaps.

F-series buyer guide

Compare the exact F-series configurations

Separate laser systems, work areas, closed bodies, safety-class variants, and missing installation evidence.

Exhaust decision

Air purifier vs inline fan

Separate outdoor extraction from filtration and preserve the P3-specific accessory restrictions.

Delivery

Delivery-path calculator

Prefill sourced package evidence and test every rectangular opening in route order.

Projects

Project-fit checker

Compare a measured flat project with documented work areas and optional 90-degree rotation.

Scale drawing

Workshop layout planner

Place the sourced closed body, support, entered operating zone, air-management equipment, and keep-clear rectangle.

Compare

Installation comparison builder

Put this evidence beside up to two other current profiles without hiding incomplete fields.

Dependencies

xTool setup builder

Map intended uses to included items, compatible choices, required accessories, and confirmations.

Placement

Operating-footprint planner

Add documented lid, service and material allowances to the closed footprint.

Exhaust

Vent-route planner

Prefill the machine note, then map segments, bends, transitions, endpoint, and confirmations without guessing airflow.

Utilities

Electrical pre-check

Inventory the machine and accessory nameplates for a qualified electrician.

Open data

Installation geometry row

Compare delivery, closed, exhaust, electrical, and numeric-clearance evidence in the downloadable dataset.

Change record

Specification tracker

Inspect the dated observation baseline and any later retained changes to manufacturer documentation.

Template

Workshop planning record

Lay out the support, operating zone, accessories, and electrical-load inventory together.

Publisher asset

Embed this True Footprint card

Copy an auto-updating iframe or dated HTML badge with evidence states, review date, and room-check backlink.

Complete plan

Laser-room setup checklist

Carry delivery, operating space, air path, utilities, materials, documentation, and professional confirmations into one record.

Official seller information

xTool buying options

Compare current configurations and seller policies after the room questions are visible. No discount is assumed.

06 · Related profiles
07 · Official evidence

Manufacturer sources used for this profile

Source links are editorial evidence, not paid links. Open the current source and match it to the exact region, model, and configuration.

08 · Plain-language answers

Common room-planning questions about F2 Ultra Single 60W MOPA

What are the published xTool F2 Ultra Single dimensions?

Official sources conflict: 11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm. Confirm the exact delivered configuration before using a numeric fit result.

Are xTool F2 Ultra Single shipping dimensions published?

A verified general shipping envelope is not published in the cited sources. The current record says: Not published in cited sources. Ask for the exact shipped SKU and bundle.

How much room does xTool F2 Ultra Single need?

The closed body is only the starting envelope. No numeric operating, service, conveyor-travel, hose-bend, cable, or accessory clearance published in cited sources. Measure the lid, controls, access panels, exhaust, cables, accessories, material travel, egress, and service access in the actual arrangement.

What exhaust and electrical evidence is recorded for xTool F2 Ultra Single?

Exhaust: 80 mm smoke-exhaust pipe in current compatibility guidance Electrical: Power-adapter input 100–240 VAC, 50/60 Hz; the family listing states 400 W maximum but does not isolate a Single-only maximum These notes organize confirmation and do not approve a ventilation or electrical design.

Use the profile to organize professional checks—not replace them.

Verify the exact machine and accessory nameplates, grounding, circuit and local requirements with a licensed electrician. Install exhaust exactly as the manufacturer directs and resolve discharge, filtration and material emissions under applicable rules. Never leave active processing unattended.

Compare xTool F2 Ultra Single 60W MOPA with your delivery path and workspace.

Use the manufacturer profile as a starting point, then enter the room and route you actually measured.

Check my room for F2 Ultra Single 60W MOPA