A record based on manufacturer sources for room and delivery planning. It does not certify the room, circuit, ventilation, material, or fire-safety setup.
Direct answer: the recorded closed body is 11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm; the unopened package is not fully published for a general current shipment. Operating clearance remains a separate check.
- Official sources conflict
- Profile reviewed
- No inferred package or clearance values
The cited official sources disagree. Confirm the exact delivered model, current manual and nameplate before entering a planning dimension or input rating.
The published machine envelope
11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm
Official values conflict; numeric fit checking is disabled.
45 lb / 20.8 kg
Verify the complete operating load and supporting surface separately.
8.66 × 8.66 in / 220 × 220 mm; 8.66 × 19.69 in / 220 × 500 mm with Auto Streamline Conveyor
Processing area is not the required room footprint.
Not published in cited sources
Published shipping weight: Not published in cited sources. Confirm the exact bundle before delivery.
60 W 1064 nm MOPA infrared only
Use current manufacturer guidance for the exact material and process.
Class 4 (MXF-K004-002)
Match the ordered and delivered model to its current instructions and site controls.
150 mm published maximum
A published maximum is not an operating clearance, material approval, focus guarantee, or proof a fixture will fit.
Requirements to carry into the site plan
Route and connection
80 mm smoke-exhaust pipe in current compatibility guidance
Nameplate input
Power-adapter input 100–240 VAC, 50/60 Hz; the family listing states 400 W maximum but does not isolate a Single-only maximum
Cooling components
No external water-cooling requirement stated in cited sources
Access in use
No numeric operating, service, conveyor-travel, hose-bend, cable, or accessory clearance published in cited sources.
Open checks remain part of the answer.
Get the shipping dimensions.
Not published in cited sources. Ask the seller or manufacturer for the exact packaged width, depth, height and weight for the SKU being delivered.
Measure access in use.
No numeric operating, service, conveyor-travel, hose-bend, cable, or accessory clearance published in cited sources. Any optional room allowance is user-selected and is not a manufacturer minimum.
Resolve the published disagreement.
11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm. Do not silently choose one value.
- This is the Single-laser configuration; it does not include the 40 W blue-light diode laser. On xTool's shared listing, select ‘Single Laser (60W MOPA Only)’. This Class 4 professional-use model does not establish permission to operate around the public or bystanders.
- The 400 W family-page maximum is not presented here as a confirmed Single-only draw.
- The support guide lists the height as 520 mm; the product page lists it as 521 mm. The 1 mm documentation difference is retained and is not usable clearance.
- The standard package lists a touchscreen and smoke-exhaust pipe; an external purifier is not assumed unless the selected bundle says so. Route outdoors or confirm an exact compatible filtration arrangement.
- As of September 14, 2026, observed seller choices included Standalone, Conveyor, and Deluxe packages; contents, prices, and availability can change.
Commissions do not change fit results or profile ordering. The seller controls availability, pricing, attribution, returns and the transaction.
Open xTool's shared F2 Ultra listing and select ‘Single Laser (60W MOPA Only)’Plan the accessories that change the room.
Compatibility below comes from the cited manufacturer material. Every accessory still needs its own footprint, load, delivery and operating-path check.
Use the measurements in context.
Room dimensions answer only part of the purchase question. Check the task and material evidence, record the software handoff, then review the exact quote.
F2 Ultra Single vs Dual
Compare laser systems, published machine weight, shared closed dimensions, and order-specific evidence gaps.
F-series buyer guideCompare the exact F-series configurations
Separate laser systems, work areas, closed bodies, safety-class variants, and missing installation evidence.
Exhaust decisionAir purifier vs inline fan
Separate outdoor extraction from filtration and preserve the P3-specific accessory restrictions.
DeliveryDelivery-path calculator
Prefill sourced package evidence and test every rectangular opening in route order.
ProjectsProject-fit checker
Compare a measured flat project with documented work areas and optional 90-degree rotation.
Scale drawingWorkshop layout planner
Place the sourced closed body, support, entered operating zone, air-management equipment, and keep-clear rectangle.
CompareInstallation comparison builder
Put this evidence beside up to two other current profiles without hiding incomplete fields.
DependenciesxTool setup builder
Map intended uses to included items, compatible choices, required accessories, and confirmations.
PlacementOperating-footprint planner
Add documented lid, service and material allowances to the closed footprint.
ExhaustVent-route planner
Prefill the machine note, then map segments, bends, transitions, endpoint, and confirmations without guessing airflow.
UtilitiesElectrical pre-check
Inventory the machine and accessory nameplates for a qualified electrician.
Open dataInstallation geometry row
Compare delivery, closed, exhaust, electrical, and numeric-clearance evidence in the downloadable dataset.
Change recordSpecification tracker
Inspect the dated observation baseline and any later retained changes to manufacturer documentation.
TemplateWorkshop planning record
Lay out the support, operating zone, accessories, and electrical-load inventory together.
Publisher assetEmbed this True Footprint card
Copy an auto-updating iframe or dated HTML badge with evidence states, review date, and room-check backlink.
Complete planLaser-room setup checklist
Carry delivery, operating space, air path, utilities, materials, documentation, and professional confirmations into one record.
Official seller informationxTool buying options
Compare current configurations and seller policies after the room questions are visible. No discount is assumed.
Compare another room-planning envelope.
- xTool F2 Ultra Dual 60W MOPA + 40W diode — 11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm
- xTool F1 Ultra — 10.75 × 14.69 × 19.37 in / 273 × 373 × 492 mm on the product page; the user guide lists 493 × 253 × 373 mm without axis labels
- xTool F2 Ultra UV 5W — 11.57 × 16.89 × 20.47 in / 294 × 429 × 520 mm
- Compare xTool F2, F1 Ultra, F2 Ultra Single, F2 Ultra Dual, and F2 Ultra UV
Manufacturer sources used for this profile
Source links are editorial evidence, not paid links. Open the current source and match it to the exact region, model, and configuration.
Common room-planning questions about F2 Ultra Single 60W MOPA
What are the published xTool F2 Ultra Single dimensions?
Official sources conflict: 11.57 × 16.88 × 20.51 in / 294 × 429 × 521 mm used for conservative display; the support guide lists 520 mm. Confirm the exact delivered configuration before using a numeric fit result.
Are xTool F2 Ultra Single shipping dimensions published?
A verified general shipping envelope is not published in the cited sources. The current record says: Not published in cited sources. Ask for the exact shipped SKU and bundle.
How much room does xTool F2 Ultra Single need?
The closed body is only the starting envelope. No numeric operating, service, conveyor-travel, hose-bend, cable, or accessory clearance published in cited sources. Measure the lid, controls, access panels, exhaust, cables, accessories, material travel, egress, and service access in the actual arrangement.
What exhaust and electrical evidence is recorded for xTool F2 Ultra Single?
Exhaust: 80 mm smoke-exhaust pipe in current compatibility guidance Electrical: Power-adapter input 100–240 VAC, 50/60 Hz; the family listing states 400 W maximum but does not isolate a Single-only maximum These notes organize confirmation and do not approve a ventilation or electrical design.
Verify the exact machine and accessory nameplates, grounding, circuit and local requirements with a licensed electrician. Install exhaust exactly as the manufacturer directs and resolve discharge, filtration and material emissions under applicable rules. Never leave active processing unattended.